What HNES is
The Heat Network Efficiency Scheme is a government programme to improve existing district and communal heating systems. It funds revenue optimisation studies that find out where a network is losing energy and money, and capital grants that pay towards the improvements the study recommends.
For an operator or housing provider it means a funded route to lower running costs, better service to residents, and a network that meets the standards it will be measured against under the Heat Network Technical Assurance Scheme.
How we help
Grant application management. If you have a heat network that may benefit from improvements, we manage the complete HNES application process, from the eligibility check to the submission.
Revenue optimisation studies. We can be relied on to identify problems and solutions in the most complex systems, from multivalent plant rooms to city-wide schemes, and thereby secure the correct capital funding to achieve measurable results.
Commercial optimisation studies. Commercial and civic buildings with highly complex heating and hot water systems may not qualify for HNES. For these we offer optimisation services that are typically self-funding from the savings.
Delivery. We do not stop at the funding. We assist with the design, implementation and management of the remedial works, and our monitoring shows the improvement as it happens so you can report back to stakeholders with evidence.
How a study runs
- Onboarding and data requests. We agree the scope, collect drawings, meter data and BMS access, and survey the plant and a representative set of connections.
- Energy balance and KPI baseline. Where the metering allows, we install monitoring or unlock BMS data to capture flow rates, return temperatures, differential pressures and pump control. The baseline is calculated against HNTAS key performance indicators.
- Issues and root causes. Faults and poor practice are logged against the equipment concerned, classified and costed.
- Measures and works packages. Improvements are grouped into packages with the savings modelled, so the capital application is built on the same figures as the study.
- Study report and grant application. The techno-economic workbook, the study binder and the capital grant application are produced from one record, so every number is traceable to its source.
The same process runs on our QA platform, which is how we keep large studies consistent across dozens of sites.
What we have learned
Across the city-wide studies the same findings came up again and again: heat meter data is used for billing but flow rates and return temperatures are not monitored or alarmed; BMS systems are operated in isolation and rarely show efficiency data; and air handling units heat and cool at the same time for years because nobody can see it. Once identified, most of these problems are straightforward to fix.
Read the city-wide HNES case study for the detail.